MIL-STD-1911A
c. Suggested color specifications.
(1) Fluorescent green, Color No. 38901 per FED-STD-595. (2) Fluorescent red, Color No. 38905 per FED-STD-595.
(3) Fluorescent orange, Color No. 38903 per FED-STD-595.
4.1.7 Design for quality control and inspection. HEO shall be designed and documented to facilitate application of effective quality control and inspection procedures. Design characteristics critical to safety shall be identified to assure that designed safety is maintained.
4.2 Design features.
4.2.1 Stored energy. The HEO shall not use stored energy for enabling or arming if sufficient energy can be derived from environments or levels of environmental stimuli present only during or after HEO deployment. If sufficient energy cannot be so derived, stored energy may be used with the following restrictions:
a. The stored energy component(s) is installed in the HEO as late as feasible in the
HEO's manufacture-to-deployment logistic cycle, and
b. The design of the HEO prohibits release of the stored energy except as a result of user-enabled actions performed in a specific sequence.
Examples of stored energy are batteries, charged capacitors, compressed air devices, explosive actuators, and loaded springs.
4.2.2 Compatibility of materials. All materials shall be chosen to be compatible and stable so that under all life-cycle conditions none of the following shall occur in an unarmed HEO:
a. Premature arming.
b. Dangerous ejection of material.
c. Deflagration or detonation of the lead or booster.
d. An increase in the sensitivity of explosive train components beyond the level appropriate for service use.
e. Compromise of safety or sterilization features.
f. Production of unacceptable levels of toxic or other hazardous materials.
10